Novasina-Humidity & Temperature Measurement
-
TAIWAN
DKSH Taiwan Ltd.
10F, No. 22, Lane 407, Ti-Ding Blvd.,
Section 2, NeiHu Technology Park
114 Taipei, Taiwan
-
Novasina QuantDat / nSens factsheet
-
Novasina QuantDat/nSens spec sheet
-
Novasina ClimMate factsheet
-
Novasina ClimMate spec
-
Novasina HygroGuard / ClimaLog / DataLog factsheet
-
Novasina Hygromaxx / Statmaxx / Tempmaxx factshet
-
Novasina HygroMaxx spec sheet
-
Novasina StatMaxx spec sheet
-
Novasina TempMaxx spec sheet
-
Application Overview
-
Application note: Bakery
-
Application note: Powder & Spices
-
Application note: Meat
-
Application note: Pharma
-
Application note: Pet Food
-
Application note: Cannabis
-
Application note: Shelf Life Simplified
- QuantDat/nSens: Multi-sensor industrial transmitter for humidity and temperature probes.
- ClimMate: Mobile reference measuring instrument for humidity and temperature in a set.
- HygroGuard/ClimaLog/DataLog: Data logger systems with internal and external sensors.
- HygroMaxx: HVAC-transmitter for humidity and temperature measurement with analogue outputs.
- StatMaxx: HVAC-thermo-hygrostat with integrated relay switches.
- TempMaxx: HVAC-temperature transmitter with integrated relay switch and analogue output.
Available Models
Technical Specifications
Power supply | 24V +/- 15% AC or DC (galvanic isolated) |
Power consumption | max. ca.3W |
---|---|
Display | Graphical display with LED backlight, 128 x 64 Pixel |
Selectable parameters | Humidity; Temperature; Mixing ratio; Water vapour partial pressure; Dew-point temperature; Specific enthalpy; Absolute humidity |
Analogue outputs | 4 scalable & adjustable analogue outputs, 0/4..20mA or 0/2..10V |
Digital outputs | RS-485 Version with relay: 2 relay contacts, switching power <=50V/2A/60W |
Housing material | ABS – lid blue RAL 5014, bottom grey RAL 7035 |
Protection class | IP54 |
Operating temperature | 0 to 50°C |
Storage temperature | -10 to + 60°C (non-condensing) |
CE-/EMC compatibility | Safety: IEC 61010-1:2010 EMC: IEC 61000-6-2:2005, EN 61000-6-2:2005 IEC: 61000-6-3:2006+A1:2010, EN 61000-6-3:2007+A1:2011 |
Multi-sensor measurement system with intelligent and robust humidity/temperature sensors and analog signal exits.
This cost-efficient solution allows the user to connect up to four external digital nSens-HT humidity and temperature sensors with one transmitter.
Key Features
- Reduced costs per measuring point thanks to multi-sensor architecture
- High accuracy, reproducible measurement, no detectable hysteresis
- Linear and fast response up to the humidity saturation level
- Automatic probe identification
- Graphics and illuminated display
- Exchangeable sensor with stored calibration data
Technical Specifications
Operation / display unit | ClimMate – multifunction handheld measuring instrument |
---|---|
Power supply | 4 x 1.5VDC alkaline batteries or USB +5V power supply unit |
Power consumption | approx. 400 mW, battery lifetime approx.1 year, confi gurable Auto-Off |
Display | Graphic display TFT 240 x 320, capacitive touch display |
Dimensions / Weight | External dimensions: W62 x D34 x H170 mm (without probe) |
Weight: | approx. 200 gr |
Measuring parameters | relative humidity; temperature (nSens-HT): accuracy see below abs.press. 800-1100mbar (integrated): accuracy @25°C +/-0.5mbar calculated parameters: mixing ratio; water vapor pressure; dew point temperature, abs. humidity; wet bulb temp.; water activity etc. |
Interfaces | USB for connection to PC / UMB for connection of external probes |
Protection class | IP54 |
Operating temperature | 0 to 50°C |
Storage temperature | -20 to +80° C |
Portable, battery-powered measuring and reference instrument for measurement of relative air humidity, temperature, absolute pressure, air velocity, air flow rate, C02 and water activity.
Key Features
- Integrated data storage
- Data visualizing software and SAL-SC humidity generator for calibration included in scope of delivery
- Large, colour LCD-Touchscreen
- Above average accuracy, reproducible measurement, no detectable hysteresis
- Linear and fast response up to humidity saturation level
- Intelligent, robust humidity/temperature sensor with stored calibration data
Technical Specifications
HygroGuard 30 | ClimaLog 30 | DataLog 30 | |
---|---|---|---|
Working range sensor | rel. humidity 0…95% Temperature -20…50°C | rel. humidity 0…95% Temperature -20…50°C Abs. pressure 0..10’000m 300…1’300 hPa | external sensors UMB-bus & 2 AI I :0…20mA U:0..10V |
Measurement principle | %RH : capacitive Temp : NTC | %RH : capacitive Temp : NTC hPa : piezo | see connected sensors! |
Accuracy | %RH : +/- 2% Temp : +/-0.3°C | %RH : +/- 2% Temp : +/-0.3°C hPa : +/-0.5 hPa at 25°C | see connected sensors! |
Resolution | %RH : 0.5% Temp : 0.1 °C | %RH : 0.5% Temp : 0.1 °C hPa : 0.1 hPa | |
Dimension | 166x78x32 mm plastic housing | 166x78x32 mm plastic housing | 166x78x32 mm plastic housing |
Weight | approx. 250 gr | approx. 250 gr | approx. 250 gr |
LCD scree | specifi c 3 line segment LCD with status, Alarm, data, time, connection | specifi c 3 line segment LCD with status, Alarm, data, time, connection | specifi c 3 line segment LCD with status, Alarm, data, time, connection |
Power supply | 4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option) | 4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option) | 4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option) |
Interfaces | USB, LAN (ethernet TCP/IP), UMB-bus | USB, LAN (ethernet TCP/IP), UMB-bus | USB, LAN (ethernet TCP/IP), UMB-bus |
Memory | 16 MB – 3’200’000 data points | 16 MB – 3’200’000 data points | 16 MB – 3’200’000 data points |
Meas. interval | 10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h | 10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h | 10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h |
Memory interval | 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h | 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h | 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h |
Operation cond | -20…+50°C / 0….95%RH (no condensation) / 10’000m a.s.l. | -20…+50°C / 0….95%RH (no condensation) / 10’000m a.s.l. | -20…+50°C / 0….95%RH (no condensation) / 10’000m a.s.l. |
Efficient Data loggers with built-in or external humidity, temperature or pressure sensor, which can be used both autonomous as a battery-powered unit or integrated into a network.
These analyzers are characterized by their diverse applicability, their high precision measurement and the recording of the desired climatic parameters. Therefore, an individual adaptation to the user’s needs is possible.
Key Features
- Possibility for room mapping with external sensors
- Large data storage of 3,2 million data points
- Large display with additional acoustic alerting
- User-friendly software for visualizing, analyzing and exporting of the data
- Possibility to connect to a LAN-network
Technical Specifications
HygroMaxx S | HygroMaxx R | HygroMaxx M | |
---|---|---|---|
Dimensions | 183 x 110 x 50 mm | 118 x 110 x 300 mm | 118 x 110 x 50 mm |
Measurement range humidity | 0 …. 100 % rH | 0 …. 100 % rH | 0 …. 100 % rH |
Measurement range temperature | -20 … +80°C / -4 … + 176 °F | -20 … +80°C / -4 … + 176 °F | -20 … +80°C / -4 … + 176 °F |
Accuracy humidity standard | +/- 3.0 % rH | +/- 3.0 % rH | +/- 3.0 % rH |
Accuracy humidity with factory calibration | +/- 1.5 % rH with 3 point calibration (11..53..90% rH) | +/- 1.5 % rH with 3 point calibration (11..53..90% rH) | +/- 1.5 % rH with 3 point calibration (11..53..90% rH) |
Display resolution | 0.1 % rH 0.1°C / 0.1°F | 0.1 % rH 0.1°C / 0.1°F | 0.1 % rH 0.1°C / 0.1°F |
Reproducibility humidity | +/- 1.0 % rH range : 10 … 85% rH | +/- 1.0 % rH range : 10 … 85% rH | +/- 1.0 % rH range : 10 … 85% rH |
Reproducibility temperature | +/- 0.1 °C range : 0 … 60°C | +/- 0.1 °C range : 0 … 60°C | +/- 0.1 °C range : 0 … 60°C |
Operating temperature | electronics : 0… +50°C sensor : -20 … + 80°C | electronics : 0… +50°C sensor : -20 … + 80°C | electronics : 0… +50°C sensor : -20 … + 80°C |
Long term stability of rH measurement | < +/- 0.5 % rH / year at max. chemical working concentration | < +/- 0.5 % rH / year at max. chemical working concentration | < +/- 0.5 % rH / year at max. chemical working concentration |
Power supply | 24 VDC +/- 25% In-Out without galvanic isolation | 24 VDC +/- 25% In-Out without galvanic isolation | 24 VDC +/- 25% In-Out without galvanic isolation |
Norm tests / storage conditions Electromagnetic compatibility | EN 61326-1 / EN 61326 / A1 | EN 61326-1 / EN 61326 / A1 | EN 61326-1 / EN 61326 / A1 |
IP-protection / protection norm | IP 54 / EN 61010-1 | IP 54 / EN 61010-1 | IP 54 / EN 61010-1 |
Storage temperature (device) | 5 …. 60 °C ( not condensing ) | 5 …. 60 °C ( not condensing ) | 5 …. 60 °C ( not condensing ) |
Storage air humidity (device) | 5 …. 80% rH ( not condensing ) | 5 …. 80% rH ( not condensing ) | 5 …. 80% rH ( not condensing ) |
The ideal Thermo-Hygrometer for measurements of relative air humidity and temperature in room or duct applications in the HVAC industry.
A digital, capacitive humidity measuring element, combined with modern electronic-architecture, allows a multifunctional usage with high measurement precision and simple application.
Key Features
- Different mounting forms for wall and duct installation
- Large, well laid-out display
- Simple to configure and calibrate
- Scalable, analogue signal: mA or V
- User-friendly menu structure with password protection
Technical Specifications
StatMaxx S | StatMaxx R | StatMaxx M | |
Dimensions | 183 x 110 x 50 mm | 118 x 110 x 300 mm | 118 x 110 x 50 mm |
Measurement range humidity | 0 …. 100 % rH | 0 …. 100 % rH | 0 …. 100 % rH |
---|---|---|---|
Measurement range temperature | -20 … +80°C | -20 … +80°C | -20 … +80°C |
Accuracy humidity-standard | +/- 3.0 % rH | +/- 3.0 % rH | +/- 3.0 % rH |
Accuracy humidity with factory calibration | +/- 1.5 % rH with 3 point calibration (11..53..90% rH) | +/- 1.5 % rH with 3 point calibration (11..53..90% rH) | +/- 1.5 % rH with 3 point calibration (11..53..90% rH) |
Display resolution | 0.1 % rH 0.1°C / 0.1°F | 0.1 % rH 0.1°C / 0.1°F | 0.1 % rH 0.1°C / 0.1°F |
Reproducibility humidity | +/- 1.0 % rH range : 10 … 85% rH | +/- 1.0 % rH range : 10 … 85% rH | +/- 1.0 % rH range : 10 … 85% rH |
Reproducibility temperature | +/- 0.1 °C range : 0 … 60°C | +/- 0.1 °C range : 0 … 60°C | +/- 0.1 °C range : 0 … 60°C |
Operating temperature | electronics : 0… +50°C sensor : -20 … + 80°C | electronics : 0… +50°C sensor : -20 … + 80°C | electronics : 0… +50°C sensor : -20 … + 80°C |
Long term stability of rH measurement | < +/- 0.5 % rH / year at max. chemical working concentration | < +/- 0.5 % rH / year at max. chemical working concentration | < +/- 0.5 % rH / year at max. chemical working concentration |
Power supply | 24 VDC +/- 20% | 24 VDC +/- 20% | 24 VDC +/- 20% |
Norm tests / storage conditions Electromagnetic compatibility | EN 61326-1 / EN 61326 A1 | EN 61326-1 / EN 61326 A1 | EN 61326-1 / EN 61326 A1 |
IP-protection / protection norm | IP 54 / EN 61010-1 | IP 54 / EN 61010-1 | IP 54 / EN 61010-1 |
Storage temperature (device) | 5 …. 60 °C ( not condensing ) | 5 …. 60 °C ( not condensing ) | 5 …. 60 °C ( not condensing ) |
Storage air humidity (device) | 5 …. 80% rH ( not condensing ) | 5 …. 80% rH ( not condensing ) | 5 …. 80% rH ( not condensing ) |
This Thermo-Hygrostat with integrated relay switch is particularly useful for monitoring, supervision and regulation tasks in HVAC applications.
Different mounting forms for wall and duct installations allow a customized use of the StatMaxx.
Key Features
- Large and well laid-out display
- Simple to configure and calibrate
- Integrated switching contact with configurable switching threshold function
- User-friendly menu structure with password protection
Technical Specifications
Dimensions | 183 x 110 x 50 mm |
Measurement range temp. measurement PT/Ni 100 | -50…+400°C 2-, 3- or 4-wire connection |
---|---|
Measurement range temp. measurement PT 1’000 | -50…+400°C 2-, 3- or 4-wire connection |
Measurement range temp. measurement Ni 1’000 | -50…+200°C 2-, 3- or 4-wire connection |
Measurement range temp. measurement Beta Therm | -20…+80°C +/- 0,2 K 2-wire connection |
Display resolution | 0.1°C / 0.1°F |
Sensor break detection | YES (display): at 2…10V and 4..20 mA = per 0 VAC / 0 mA |
Repeatability temperature | depending on probe according to DIN EN 60751 AA, A, B, 1/3B, C |
Operating temperature | electronics : -10…+50°C sensor : -50…+400°C |
Long term stability of rH measurement | < +/- 0.5 % rH / year at max. chemical working concentration |
Power supply | 18…35 (24 VDC +/- 25%) without galvanic isolation 50…100mA depending on initial condition |
Accuracy | +/- 0.15% FS accuracy without sensor element over full measurement range |
Password protection | YES 4-digit code for all settings |
Special funtions: Alarm function | High, Low, Hysteresis, Delay, NC or NO (On/OFF) |
2-point control fuction | Setpoint, Hysteresis, Delay, NC or NO (On/OFF) |
Norm tests/storage conditions: Electromagnetic compatibility | IEC 61000-6-2 / IEC 61000-6-4 / EN 61000-6-2 / EN 61000-6-4 |
IP-protection / CE-Norm | IP 41 / EN 61010-1 |
Storage temperature (device) | 5 …. 60 °C ( not condensing ) |
Storage air humidity (device) | 5 …. 80% rH ( not condensing ) |
Universal temperature transmitter with analogue output and relay switch especially developed for demanding HVAC applications.
This analyzer is characterized by its possibility to connect with various temperature sensors. Further, it is simple to configure, to mount and to calibrate.
Key Features
- Connection with standard PT100, PT1000 and NTC sensors
- Large and well laid-out display
- Integrated switching contact with configurable switching threshold function
- Scalable, analogue signal: mA or V
- User-friendly menu structure with password protection
Application Notes
Success Stories
Successfully Flowing Into New Market Segments
Though Novasina’s product has been widely accepted in the meat processing segment, in Japan it had not made much headway in other business segments. Novasina needed to identify opportunities in other industries to grow its business presence in Japan.
Key Industries
- Agriculture
- Biopharmaceutical and Biotechnology
- Cosmetics & Personal Care
- Education & Academics
- Electronics
- Food & Beverage
- Optical
- Pharmaceutical
- Semiconductor, Solar & Electronics
- Service
- Textile
Brand
Since its establishment more than 50 years ago, the company Novasina has specialised in the accurate measuring of air and material humidity. Novasina fully develops and produces precision measuring devices and includes always its long lasting know-how. We are proud of the “SWISS MADE” label, which guarantees our customers highest quality, innovation and longevity.
Download now